3677
Global
Height rank

Capital Gate Tower

Abu Dhabi
Height 164.7 m / 540 ft
Floors 36
Official Name
The current legal building name.

Capital Gate Tower

Other Names
Other names the building has commonly been known as, including former names, common informal names, local names, etc.

Andaz Capital Gate Abu Dhabi

Type
CTBUH collects data on two major types of tall structures: 'Buildings' and 'Telecommunications / Observation Towers.' A 'Building' is a structure where at least 50% of the height is occupied by usable floor area. A 'Telecommunications / Observation Tower' is a structure where less than 50% of the structure's height is occupied by usable floor area. Only 'Buildings' are eligible for the CTBUH 'Tallest Buildings' lists.

Building

Status
Completed
Architecturally Topped Out
Structurally Topped Out
Under Construction
Proposed
On Hold
Never Completed
Vision
Competition Entry
Canceled
Proposed Renovation
Under Renovation
Renovated
Under Demolition
Demolished

Completed, 2011

Country
The CTBUH follows the United Nations's definition of Country, and thus uses the lists and codes established by that organization.

United Arab Emirates

City
The CTBUH follows the United Nations's definition of City, and thus uses the lists and codes established by that organization.

Abu Dhabi

Postal Code

5564

Function
A single-function tall building is defined as one where 85% or more of its usable floor area is dedicated to a single usage. Thus a building with 90% office floor area would be said to be an "office" building, irrespective of other minor functions it may also contain.

A mixed-use tall building contains two or more functions (or uses), where each of the functions occupy a significant proportion of the tower's total space. Support areas such as car parks and mechanical plant space do not constitute mixed-use functions. Functions are denoted on CTBUH "Tallest Building" lists in descending order, e.g., "hotel/office" indicates hotel function above office function.

hotel / office

Structural Material
Steel
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from steel. Note that a building of steel construction with a floor system of concrete planks or concrete slab on top of steel beams is still considered a “steel” structure as the concrete elements are not acting as the primary structure.

Reinforced Concrete
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from concrete which has been cast in place and utilizes steel reinforcement bars.

Precast Concrete
Both the main vertical/lateral structural elements and the floor spanning system are constructed from steel reinforced concrete which has been precast as individual components and assembled together on-site.

Mixed-Structure
Utilizes distinct systems (e.g. steel, concrete, timber), one on top of the other. For example, a steel/concrete indicates a steel structural system located on top of a concrete structural system, with the opposite true of concrete/steel.

Composite
A combination of materials (e.g. steel, concrete, timber) are used together in the main structural elements. Examples include buildings which utilize: steel columns with a floor system of reinforced concrete beams; a steel frame system with a concrete core; concrete-encased steel columns; concrete-filled steel tubes; etc. Where known, the CTBUH database breaks out the materials used in a composite building’s core, columns, and floor spanning separately.

composite

Official Website

Capital Gate Tower

Height
Architectural
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the architectural top of the building, including spires, but not including antennae, signage, flag poles or other functional-technical equipment. This measurement is the most widely utilized and is employed to define the Council on Tall Buildings and Urban Habitat (CTBUH) rankings of the "World's Tallest Buildings."

164.7 m / 540 ft

To Tip
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest point of the building, irrespective of material or function of the highest element (i.e., including antennae, flagpoles, signage and other functional-technical equipment).
164.7 m / 540 ft
Occupied
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest occupied floor within the building.
152.3 m / 500 ft
Observatory
88.4 m / 290 ft
Helipad
Height, measured from the level of the lowest, significant, open-air, pedestrian entrance, to the building's helipad.
164.6 m / 540 ft
Floors Above Ground
The number of floors above ground should include the ground floor level and be the number of main floors above ground, including any significant mezzanine floors and major mechanical plant floors. Mechanical mezzanines should not be included if they have a significantly smaller floor area than the major floors below. Similarly, mechanical penthouses or plant rooms protruding above the general roof area should not be counted. Note: CTBUH floor counts may differ from published accounts, as it is common in some regions of the world for certain floor levels not to be included (e.g., the level 4, 14, 24, etc. in Hong Kong).

36

Floors Below Ground
The number of floors below ground should include all major floors located below the ground floor level.

1

# of Hotel Rooms
Number of Hotel Rooms refers to the total number of hotel rooms contained within a particular building.

189

# of Elevators
Number of Elevators refers to the total number of elevator cars (not shafts) contained within a particular building (including public, private and freight elevators).

16

Top Elevator Speed
Top Elevator Speed refers to the top speed capable of being achieved by an elevator within a particular building, measured in meters per second.

3.5 m/s

Tower GFA
Tower GFA refers to the total gross floor area within the tower footprint, not including adjoining podiums, connected buildings or other towers within the development.

53,100 m² / 571,564 ft²

Rankings
#
3677
Tallest in the World
#
314
Tallest in Middle East
#
38
Tallest in Abu Dhabi
#
684
Tallest Mixed-use Building in the World
#
66
Tallest Mixed-use Building in Middle East
#
47
Tallest Mixed-use Building in United Arab Emirates
#
9
Tallest Mixed-use Building in Abu Dhabi
#
627
Tallest Composite Building in the World
#
15
Tallest Composite Building in Middle East
#
6
Tallest Composite Building in United Arab Emirates
#
1
Tallest Composite Building in Abu Dhabi
Construction Schedule
2005

Proposed

2007

Construction Start

2011

Completed

Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Structural Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

MEP Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Building Monitoring
Material Supplier

Material Supplier refers to organizations which supplied significant systems/materials for a building project (e.g. elevator suppliers, facade suppliers, etc).

Elevator
Owner/Developer
ADNEC Group
Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Structural Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

MEP Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

Project Manager

The CTBUH lists a project manager when a specific firm has been commissioned to oversee this aspect of a tall building’s design/construction. When the project management efforts are handled by the developer, main contract, or architect, this field will be omitted.

Mace Limited
Main Contractor

The main contractor is the supervisory contractor of all construction work on a project, management of sub-contractors and vendors, etc. May be referred to as "Construction Manager," however, for consistency CTBUH uses the term "Main Contractor" exclusively.

Al Habtoor Engineering Enterprises
Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Building Monitoring
Marketing
Wordsearch
Property Management
Hyatt Hotels Corporation
Wind
BMT Fluid Mechanics Ltd.
(not specified)
Hyder Consulting
Material Supplier

Material Supplier refers to organizations which supplied significant systems/materials for a building project (e.g. elevator suppliers, facade suppliers, etc).

Elevator
Paint/Coating
AkzoNobel
Steel
Eversendai Engineering Qatar

CTBUH Initiatives

Capital Gate Tower Chosen as Featured Building

1 July 2012 - Featured Building

CTBUH Leads Discussions at Cityscape Abu Dhabi

1 May 2012 - Event

Research

01 December 2016

An Overview of Structural & Aesthetic Developments in Tall Buildings Using Exterior Bracing & Diagrid Systems

Kheir Al-Kodmany, University of Illinois; Mir M. Ali, University of Illinois at Urbana-Champaign

There is much architectural and engineering literature which discusses the virtues of exterior bracing and diagrid systems in regards to sustainability - two systems which...

About Capital Gate Tower

The Tower’s curvaceous shape draws strongly on the sea and desert—two elements that have great resonance in Abu Dhabi. The building’s form represents a swirling spiral of sand. The curved canopy, known as the “Splash,” which runs over the adjoining grandstand and rises up on one side of the building, creates a wave-like effect while shading the façade.

The tower was constructed with an 18 degree westward lean, holding the Guinness World Record for the “world’s furthest leaning manmade tower.” The floor plates change shape and orientation to create the distinctive overhang moving from “curved triangular” to “curved rectangular,” while increasing in overall size and migrating from east to west as they progress up the tower. The building has a completely asymmetric shape—no two rooms are the same and all 12,500 panes of glass on the façade are a different size. A diagrid structural system was utilized in which all 8,250 steel diagrid members are of different thicknesses, length and orientation and each of the 822 diagrid nodes are of a different size and angular configuration.

01 December 2016

An Overview of Structural & Aesthetic Developments in Tall Buildings Using Exterior Bracing & Diagrid Systems

Kheir Al-Kodmany, University of Illinois; Mir M. Ali, University of Illinois at Urbana-Champaign

There is much architectural and engineering literature which discusses the virtues of exterior bracing and diagrid systems in regards to sustainability - two systems which...

01 December 2016

The Emergence of the Diagrid - It’s All About the Node

Terri Meyer Boake, University of Waterloo

The diagrid structural system for constructing tall buildings is a recent invention. Debuting in 2004 with the construction of the Swiss Re Tower in London,...

01 August 2013

The Use of Stainless Steel in Second-Skin Façades

Catherine Houska, TMR Consulting

Exterior walls are being transformed from relatively simple climate-defensive mechanisms to more active membranes that screen weather to reduce energy requirements.

12 June 2012

Case Study: Capital Gate, Abu Dhabi

Jeff Schofield, RMJM

Throughout history, a strong link has existed between iconic architecture and exhibitions. In 2005, the Abu Dhabi National Exhibitions Company (ADNEC) was created to drive...

1 July 2012

Capital Gate Tower Chosen as Featured Building

Throughout history, a strong link has existed between iconic architecture and exhibitions. One of the best known examples is Paris’ Eiffel Tower, Capital Gate is Abu Dhabi's icon.

1 May 2012

CTBUH Leads Discussions at Cityscape Abu Dhabi

CTBUH Public Affairs Manager Kevin Brass chaired the Middle East Real Estate Summit, the annual event for the regional property industry.