548
Global
Height rank

Chifley Tower

Sydney
Height 244.0 m / 801 ft
Floors 50
Official Name
The current legal building name.

Chifley Tower

Type
CTBUH collects data on two major types of tall structures: 'Buildings' and 'Telecommunications / Observation Towers.' A 'Building' is a structure where at least 50% of the height is occupied by usable floor area. A 'Telecommunications / Observation Tower' is a structure where less than 50% of the structure's height is occupied by usable floor area. Only 'Buildings' are eligible for the CTBUH 'Tallest Buildings' lists.

Building

Status
Completed
Architecturally Topped Out
Structurally Topped Out
Under Construction
Proposed
On Hold
Never Completed
Vision
Competition Entry
Canceled
Proposed Renovation
Under Renovation
Renovated
Under Demolition
Demolished

Completed, 1992

Country
The CTBUH follows the United Nations's definition of Country, and thus uses the lists and codes established by that organization.

Australia

City
The CTBUH follows the United Nations's definition of City, and thus uses the lists and codes established by that organization.

Sydney

Postal Code

2000

Function
A single-function tall building is defined as one where 85% or more of its usable floor area is dedicated to a single usage. Thus a building with 90% office floor area would be said to be an "office" building, irrespective of other minor functions it may also contain.

A mixed-use tall building contains two or more functions (or uses), where each of the functions occupy a significant proportion of the tower's total space. Support areas such as car parks and mechanical plant space do not constitute mixed-use functions. Functions are denoted on CTBUH "Tallest Building" lists in descending order, e.g., "hotel/office" indicates hotel function above office function.

office

Structural Material
Steel
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from steel. Note that a building of steel construction with a floor system of concrete planks or concrete slab on top of steel beams is still considered a “steel” structure as the concrete elements are not acting as the primary structure.

Reinforced Concrete
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from concrete which has been cast in place and utilizes steel reinforcement bars.

Precast Concrete
Both the main vertical/lateral structural elements and the floor spanning system are constructed from steel reinforced concrete which has been precast as individual components and assembled together on-site.

Mixed-Structure
Utilizes distinct systems (e.g. steel, concrete, timber), one on top of the other. For example, a steel/concrete indicates a steel structural system located on top of a concrete structural system, with the opposite true of concrete/steel.

Composite
A combination of materials (e.g. steel, concrete, timber) are used together in the main structural elements. Examples include buildings which utilize: steel columns with a floor system of reinforced concrete beams; a steel frame system with a concrete core; concrete-encased steel columns; concrete-filled steel tubes; etc. Where known, the CTBUH database breaks out the materials used in a composite building’s core, columns, and floor spanning separately.

steel

Energy Label

4.5 Star NABERS Energy Rating

Height
Architectural
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the architectural top of the building, including spires, but not including antennae, signage, flag poles or other functional-technical equipment. This measurement is the most widely utilized and is employed to define the Council on Tall Buildings and Urban Habitat (CTBUH) rankings of the "World's Tallest Buildings."

244.0 m / 801 ft

To Tip
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest point of the building, irrespective of material or function of the highest element (i.e., including antennae, flagpoles, signage and other functional-technical equipment).
244.1 m / 801 ft
Occupied
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest occupied floor within the building.
189.0 m / 620 ft
Floors Above Ground
The number of floors above ground should include the ground floor level and be the number of main floors above ground, including any significant mezzanine floors and major mechanical plant floors. Mechanical mezzanines should not be included if they have a significantly smaller floor area than the major floors below. Similarly, mechanical penthouses or plant rooms protruding above the general roof area should not be counted. Note: CTBUH floor counts may differ from published accounts, as it is common in some regions of the world for certain floor levels not to be included (e.g., the level 4, 14, 24, etc. in Hong Kong).

50

Floors Below Ground
The number of floors below ground should include all major floors located below the ground floor level.

4

# of Elevators
Number of Elevators refers to the total number of elevator cars (not shafts) contained within a particular building (including public, private and freight elevators).

26

Tower GFA
Tower GFA refers to the total gross floor area within the tower footprint, not including adjoining podiums, connected buildings or other towers within the development.

90,000 m² / 968,752 ft²

Rankings
#
548
Tallest in the World
#
13
Tallest in Oceania
#
1
Tallest in Sydney
#
233
Tallest Office Building in the World
#
6
Tallest Office Building in Oceania
#
6
Tallest Office Building in Australia
#
1
Tallest Office Building in Sydney
#
46
Tallest Steel Building in the World
#
1
Tallest Steel Building in Oceania
#
1
Tallest Steel Building in Australia
#
1
Tallest Steel Building in Sydney
Construction Schedule
1988

Construction Start

1992

Completed

2008

Retrofit Start

2014

Retrofit End

Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Structural Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Retrofit Companies Involved

Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Quantity Surveyor
Owner
Current
Reco Bathurst Pty Ltd
Developer
Bond Corporation; Kumagai Gumi
Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Structural Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

Main Contractor

The main contractor is the supervisory contractor of all construction work on a project, management of sub-contractors and vendors, etc. May be referred to as "Construction Manager," however, for consistency CTBUH uses the term "Main Contractor" exclusively.

Multiplex Construction
Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Property Management
JLL

Retrofit Companies Involved

Structural Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

D’Ambrosio Consulting Pty Ltd
MEP Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

GWA Consultants
Project Manager

The CTBUH lists a project manager when a specific firm has been commissioned to oversee this aspect of a tall building’s design/construction. When the project management efforts are handled by the developer, main contract, or architect, this field will be omitted.

Crown Project Services; JLL
Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Building Monitoring
Honeywell
Fire
Harris Page and Associates
Quantity Surveyor

CTBUH Awards & Distinctions

Performance Award 2015 Winner

2015 CTBUH Awards

CTBUH Initiatives

Warm Weather Spaces Walking Tours 2015

17 September 2015 - Event

Videos

12 November 2015 | Sydney

2015 Awards - Session 2 Q&A

Nicholas E. Billotti, Chairman, Turner International, Michael George, Regional Director, JLL, Alberto Alarcon, Chief Executive Officer, HOLEDECK, Maria Ramirez, Managing Director, HOLEDECK, and Mun Summ...

12 November 2015 | Sydney

2015 Awards - Session 2 Q&A

Nicholas E. Billotti, Chairman, Turner International, Michael George, Regional Director, JLL, Alberto Alarcon, Chief Executive Officer, HOLEDECK, Maria Ramirez, Managing Director, HOLEDECK, and Mun Summ...

12 November 2015 | Sydney

Interview: Chifley Tower

Michael George, Regional Director, JLL, is interviewed by Chris Bentley regarding the Chifley Tower in Sydney, the recipient of the 2015 Tall Building Performance Award,...

12 November 2015 | Sydney

Managing Performance Through Incremental Improvements: Chifley Tower, Sydney

Michael George, Regional Director, JLL, speaks at the 14th Annual Best Tall Building Symposium in a presentation entitled "Managing Performance Through Incremental Improvements: Chifley Tower,...

26 October 2015 | Sydney

Global Best Practice for Creating Socially Engaging Tall Buildings within their Communities

Driven by diverse factors that include the constant march of urbanisation, the changing demographic of the workforce, changes to the nature of city working, the...

18 October 2012 | Sydney

Fazlur Kahn Lifetime Achievement Medal: A Lifetime’s Engineering Collaboration

The partnership between Charles Thornton and Richard Tomasetti has provided the backbone for many of the most dramatic and innovative tall buildings around the world....