5127
Global
Height rank

Torre Libertad

Mexico City
Height 150.0 m / 492 ft
Floors 31
Official Name
The current legal building name.

Torre Libertad

Other Names
Other names the building has commonly been known as, including former names, common informal names, local names, etc.

St. Regis Hotel & Residences

Type
CTBUH collects data on two major types of tall structures: 'Buildings' and 'Telecommunications / Observation Towers.' A 'Building' is a structure where at least 50% of the height is occupied by usable floor area. A 'Telecommunications / Observation Tower' is a structure where less than 50% of the structure's height is occupied by usable floor area. Only 'Buildings' are eligible for the CTBUH 'Tallest Buildings' lists.

Building

Status
Completed
Architecturally Topped Out
Structurally Topped Out
Under Construction
Proposed
On Hold
Never Completed
Vision
Competition Entry
Canceled
Proposed Renovation
Under Renovation
Renovated
Under Demolition
Demolished

Completed, 2009

Country
The CTBUH follows the United Nations's definition of Country, and thus uses the lists and codes established by that organization.

Mexico

City
The CTBUH follows the United Nations's definition of City, and thus uses the lists and codes established by that organization.

Mexico City

Postal Code

06500

Function
A single-function tall building is defined as one where 85% or more of its usable floor area is dedicated to a single usage. Thus a building with 90% office floor area would be said to be an "office" building, irrespective of other minor functions it may also contain.

A mixed-use tall building contains two or more functions (or uses), where each of the functions occupy a significant proportion of the tower's total space. Support areas such as car parks and mechanical plant space do not constitute mixed-use functions. Functions are denoted on CTBUH "Tallest Building" lists in descending order, e.g., "hotel/office" indicates hotel function above office function.

residential / hotel

Structural Material
Steel
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from steel. Note that a building of steel construction with a floor system of concrete planks or concrete slab on top of steel beams is still considered a “steel” structure as the concrete elements are not acting as the primary structure.

Reinforced Concrete
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from concrete which has been cast in place and utilizes steel reinforcement bars.

Precast Concrete
Both the main vertical/lateral structural elements and the floor spanning system are constructed from steel reinforced concrete which has been precast as individual components and assembled together on-site.

Mixed-Structure
Utilizes distinct systems (e.g. steel, concrete, timber), one on top of the other. For example, a steel/concrete indicates a steel structural system located on top of a concrete structural system, with the opposite true of concrete/steel.

Composite
A combination of materials (e.g. steel, concrete, timber) are used together in the main structural elements. Examples include buildings which utilize: steel columns with a floor system of reinforced concrete beams; a steel frame system with a concrete core; concrete-encased steel columns; concrete-filled steel tubes; etc. Where known, the CTBUH database breaks out the materials used in a composite building’s core, columns, and floor spanning separately.

composite

Core
Reinforced Concrete
Columns
Concrete Encased Steel
Floor Spanning
Steel
Height
Architectural
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the architectural top of the building, including spires, but not including antennae, signage, flag poles or other functional-technical equipment. This measurement is the most widely utilized and is employed to define the Council on Tall Buildings and Urban Habitat (CTBUH) rankings of the "World's Tallest Buildings."

150.0 m / 492 ft

To Tip
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest point of the building, irrespective of material or function of the highest element (i.e., including antennae, flagpoles, signage and other functional-technical equipment).
150.0 m / 492 ft
Occupied
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest occupied floor within the building.
138.0 m / 453 ft
Helipad
Height, measured from the level of the lowest, significant, open-air, pedestrian entrance, to the building's helipad.
144.5 m / 474 ft
Floors Above Ground
The number of floors above ground should include the ground floor level and be the number of main floors above ground, including any significant mezzanine floors and major mechanical plant floors. Mechanical mezzanines should not be included if they have a significantly smaller floor area than the major floors below. Similarly, mechanical penthouses or plant rooms protruding above the general roof area should not be counted. Note: CTBUH floor counts may differ from published accounts, as it is common in some regions of the world for certain floor levels not to be included (e.g., the level 4, 14, 24, etc. in Hong Kong).

31

Floors Below Ground
The number of floors below ground should include all major floors located below the ground floor level.

7

# of Apartments
Number of Apartments refers to the total number of residential units (including both rental units and condominiums) contained within a particular building.

102

# of Hotel Rooms
Number of Hotel Rooms refers to the total number of hotel rooms contained within a particular building.

189

# of Parking Spaces
Number of Parking Spaces refers to the total number of car parking spaces contained within a particular building.

1200

# of Elevators
Number of Elevators refers to the total number of elevator cars (not shafts) contained within a particular building (including public, private and freight elevators).

15

Tower GFA
Tower GFA refers to the total gross floor area within the tower footprint, not including adjoining podiums, connected buildings or other towers within the development.

78,900 m² / 849,273 ft²

Rankings
#
5127
Tallest in the World
#
38
Tallest in Mexico
#
23
Tallest in Mexico City
#
839
Tallest Mixed-use Building in the World
#
129
Tallest Mixed-use Building in North America
#
12
Tallest Mixed-use Building in Mexico
#
4
Tallest Mixed-use Building in Mexico City
#
702
Tallest Composite Building in the World
#
91
Tallest Composite Building in North America
#
9
Tallest Composite Building in Mexico
#
7
Tallest Composite Building in Mexico City
Construction Schedule
2004

Proposed

2005

Construction Start

2009

Completed

Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Owner/Developer
Grupo Ideurban
Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Architect of Record

Usually takes on the balance of the architectural effort not executed by the "Design Architect," typically responsible for the construction documents, conforming to local codes, etc. May often be referred to as "Executive," "Associate," or "Local" Architect, however, for consistency CTBUH uses the term "Architect of Record" exclusively.

Grupo Ideurban
Structural Engineer
(not specified)
Enrique Martinex Romero
MEP Engineer
(not specified)
CYVSA
Main Contractor

The main contractor is the supervisory contractor of all construction work on a project, management of sub-contractors and vendors, etc. May be referred to as "Construction Manager," however, for consistency CTBUH uses the term "Main Contractor" exclusively.

Grupo Ideurban
Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Façade

These are firms that consult on the design of a building's façade. May often be referred to as "Cladding," "Envelope," "Exterior Wall," or "Curtain Wall" Consultant, however, for consistency CTBUH uses the term "Façade Consultant" exclusively.

Vidaris, Inc.

About Torre Libertad

Torre Libertad is on the Paseo de la Reforma, Mexico City’s grand historic boulevard. Near Chapultapec Park on a stretch of the thoroughfare recently reinvigorated by new development, the building overlooks a prominent roundabout featuring the landmark Diana Fountain. In response to this historic site, the design of the tower is simple and sculptural. The tower is a curved, triangular form with a carefully proportioned curtain wall of clear glass and white aluminum sunshades. The corner facing the Diana Fountain features an undulating facet that catches the changing light while framing a view of the fountain. This facet tapers as it reaches toward the sky and curves outward as it approaches the ground, creating a canopy over the entry.

The tower houses the St. Regis Hotel, with 189 guest rooms, and the St. Regis Residences, with 100 apartments. The tower’s plan and structural system allow for generous layouts for each unit. Residents and visitors enter the ground-floor entrance into a lobby atrium. The hotel reception is on the fourth level, which opens onto a wide landscaped terrace.