408
Global
Height rank

Devon Energy Center

Oklahoma City
Height 257.2 m / 844 ft
Floors 52
Official Name
The current legal building name.

Devon Energy Center

Other Names
Other names the building has commonly been known as, including former names, common informal names, local names, etc.

Devon Energy Tower, Devon Tower, Devon Headquarters

Type
CTBUH collects data on two major types of tall structures: 'Buildings' and 'Telecommunications / Observation Towers.' A 'Building' is a structure where at least 50% of the height is occupied by usable floor area. A 'Telecommunications / Observation Tower' is a structure where less than 50% of the structure's height is occupied by usable floor area. Only 'Buildings' are eligible for the CTBUH 'Tallest Buildings' lists.

Building

Status
Completed
Architecturally Topped Out
Structurally Topped Out
Under Construction
Proposed
On Hold
Never Completed
Vision
Competition Entry
Canceled
Proposed Renovation
Under Renovation
Renovated
Under Demolition
Demolished

Completed, 2012

Country
The CTBUH follows the United Nations's definition of Country, and thus uses the lists and codes established by that organization.

United States

City
The CTBUH follows the United Nations's definition of City, and thus uses the lists and codes established by that organization.

Oklahoma City

Postal Code

73102

Function
A single-function tall building is defined as one where 85% or more of its usable floor area is dedicated to a single usage. Thus a building with 90% office floor area would be said to be an "office" building, irrespective of other minor functions it may also contain.

A mixed-use tall building contains two or more functions (or uses), where each of the functions occupy a significant proportion of the tower's total space. Support areas such as car parks and mechanical plant space do not constitute mixed-use functions. Functions are denoted on CTBUH "Tallest Building" lists in descending order, e.g., "hotel/office" indicates hotel function above office function.

office

Structural Material
Steel
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from steel. Note that a building of steel construction with a floor system of concrete planks or concrete slab on top of steel beams is still considered a “steel” structure as the concrete elements are not acting as the primary structure.

Reinforced Concrete
Both the main vertical/lateral structural elements and the floor spanning systems are constructed from concrete which has been cast in place and utilizes steel reinforcement bars.

Precast Concrete
Both the main vertical/lateral structural elements and the floor spanning system are constructed from steel reinforced concrete which has been precast as individual components and assembled together on-site.

Mixed-Structure
Utilizes distinct systems (e.g. steel, concrete, timber), one on top of the other. For example, a steel/concrete indicates a steel structural system located on top of a concrete structural system, with the opposite true of concrete/steel.

Composite
A combination of materials (e.g. steel, concrete, timber) are used together in the main structural elements. Examples include buildings which utilize: steel columns with a floor system of reinforced concrete beams; a steel frame system with a concrete core; concrete-encased steel columns; concrete-filled steel tubes; etc. Where known, the CTBUH database breaks out the materials used in a composite building’s core, columns, and floor spanning separately.

concrete

Energy Label

LEED Gold

Official Website

Devon Headquarters

Height
Architectural
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the architectural top of the building, including spires, but not including antennae, signage, flag poles or other functional-technical equipment. This measurement is the most widely utilized and is employed to define the Council on Tall Buildings and Urban Habitat (CTBUH) rankings of the "World's Tallest Buildings."

257.2 m / 844 ft

To Tip
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest point of the building, irrespective of material or function of the highest element (i.e., including antennae, flagpoles, signage and other functional-technical equipment).
257.4 m / 844 ft
Occupied
Height is measured from the level of the lowest, significant, open-air, pedestrian entrance to the highest occupied floor within the building.
227.3 m / 746 ft
Floors Above Ground
The number of floors above ground should include the ground floor level and be the number of main floors above ground, including any significant mezzanine floors and major mechanical plant floors. Mechanical mezzanines should not be included if they have a significantly smaller floor area than the major floors below. Similarly, mechanical penthouses or plant rooms protruding above the general roof area should not be counted. Note: CTBUH floor counts may differ from published accounts, as it is common in some regions of the world for certain floor levels not to be included (e.g., the level 4, 14, 24, etc. in Hong Kong).

52

Floors Below Ground
The number of floors below ground should include all major floors located below the ground floor level.

2

# of Parking Spaces
Number of Parking Spaces refers to the total number of car parking spaces contained within a particular building.

2793

# of Elevators
Number of Elevators refers to the total number of elevator cars (not shafts) contained within a particular building (including public, private and freight elevators).

52

Top Elevator Speed
Top Elevator Speed refers to the top speed capable of being achieved by an elevator within a particular building, measured in meters per second.

6.1 m/s

Tower GFA
Tower GFA refers to the total gross floor area within the tower footprint, not including adjoining podiums, connected buildings or other towers within the development.

125,812 m² / 1,354,229 ft²

Rankings
#
408
Tallest in the World
#
65
Tallest in North America
#
1
Tallest in Oklahoma City
#
173
Tallest Office Building in the World
#
38
Tallest Office Building in North America
#
35
Tallest Office Building in United States
#
1
Tallest Office Building in Oklahoma City
#
171
Tallest Concrete Building in the World
#
24
Tallest Concrete Building in North America
#
19
Tallest Concrete Building in United States
#
1
Tallest Concrete Building in Oklahoma City
Construction Schedule
2007

Proposed

2009

Construction Start

2012

Completed

Developer
Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Structural Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

MEP Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Façade

These are firms that consult on the design of a building's façade. May often be referred to as "Cladding," "Envelope," "Exterior Wall," or "Curtain Wall" Consultant, however, for consistency CTBUH uses the term "Façade Consultant" exclusively.

Interiors
Material Supplier

Material Supplier refers to organizations which supplied significant systems/materials for a building project (e.g. elevator suppliers, facade suppliers, etc).

Cladding
Elevator
Owner
Devon Energy
Developer
Architect
Design

Usually involved in the front end design, with a "typical" condition being that of a leadership role through either Schematic Design or Design Development, and then a monitoring role through the CD and CA phases.

Architect of Record

Usually takes on the balance of the architectural effort not executed by the "Design Architect," typically responsible for the construction documents, conforming to local codes, etc. May often be referred to as "Executive," "Associate," or "Local" Architect, however, for consistency CTBUH uses the term "Architect of Record" exclusively.

Kendall / Heaton Associates
Structural Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

MEP Engineer
Design

The Design Engineer is usually involved in the front end design, typically taking the leadership role in the Schematic Design and Design Development, and then a monitoring role through the CD and CA phases.

Main Contractor

The main contractor is the supervisory contractor of all construction work on a project, management of sub-contractors and vendors, etc. May be referred to as "Construction Manager," however, for consistency CTBUH uses the term "Main Contractor" exclusively.

Holder Flintco Joint Venture; Flintco; Holder Construction Company
Other Consultant

Other Consultant refers to other organizations which provided significant consultation services for a building project (e.g. wind consultants, environmental consultants, fire and life safety consultants, etc).

Façade

These are firms that consult on the design of a building's façade. May often be referred to as "Cladding," "Envelope," "Exterior Wall," or "Curtain Wall" Consultant, however, for consistency CTBUH uses the term "Façade Consultant" exclusively.

Interiors
Material Supplier

Material Supplier refers to organizations which supplied significant systems/materials for a building project (e.g. elevator suppliers, facade suppliers, etc).

Cladding
Elevator

CTBUH Awards & Distinctions

Best Tall Building Americas 2013 Award of Excellence

2013 CTBUH Awards

CTBUH Initiatives

Devon Energy Center Chosen as Featured Building

1 October 2013 - Featured Building

Videos

18 October 2016 | Oklahoma City

CTBUH 2016 China Conference - Panel,"Tall Buildings and Context: How High Can We Go and Why Should We?"

Tuesday, October 18, 2016. Shenzhen, China. Ron Klemencic, Magnusson Klemencic Associates; Karl Almstead, Turner Construction Company; Andrew Nicholson, CBRE; Jon Pickard, Pickard Chilton; Ian Smith,...

About Devon Energy Center

Devon Energy Center creates a focal point for the company and Oklahoma City by integrating civic-scaled spaces as a vital component of its overall development. It consolidates Devon’s Oklahoma City–based workforce into a single state-of-the-art facility with numerous amenities.

The three-sided tower evolved in part from Devon’s desire to not “turn its back” on any part of the city. Its orientation and placement provide southern exposure to the park while minimizing solar gain. Its form resulted in highly efficient tripartite floor plates averaging 28,000 square feet that accommodate up to 12 full-corner offices. Responsive to the theme of a “right to light” for all occupants, the 10-foot floor-to-ceiling glazing allows daylight deep into the Tower as well as expansive views. All perimeter offices have floor-to-ceiling glass to maximize daylight. The curtain wall consists of continuous high-performance clear glass with a low-E coating that maximizes daylight, while also reducing heat gain.

With a highly articulated structure, the Rotunda is a grand civic-scaled space with glass walls, a series of balconies, and sky-lit roof. It regularly serves as a venue for special events. Unifying the entire complex within the city, the jewel-like Rotunda symbolically and literally connects the cardinal directions, punctuating the urban axis of Harvey Street. The Rotunda provides 12,522 square feet (1,163 square meters) of welcome assembly space and has hosted fund-raisers, holiday balls, corporate dinners, and civic gatherings.

The Podium contains training and meeting spaces as well as visitor and occupant services. A promenade extending its length creates a glazed day-lit interior corridor. At street level, it provides public access to various amenities, including restaurants, and includes a series of indoor seating areas for dining and overlooking the park.

Defining an urban edge, the Auditorium is a prominent, but intimately scaled, multi-use venue for both corporate and public events. Although nestled into the landscaped park, its strong presence activates street life and supports the downtown’s vitality, while providing dramatic views of downtown and Myriad Botanical Gardens.

The building is among the largest LEED-NC Gold-certified buildings worldwide. The chosen site has direct access to public transit. Construction of the building minimally impacted the natural environment by diverting 68,000 tons (61,669 metric tons) of waste and concrete from landfills and recycling 100 percent of a demolished parking deck on the site. The building also performs well operationally. Potable water consumption is reduced by 50 percent through landscape design and irrigation; overall water use is reduced by 40 percent. Energy use is modulated by district cooling with on-site co-generation, personal comfort control for 50 percent of occupants and personal lighting control for 90 percent of occupants.

CTBUH Awards & Distinctions

Best Tall Building Americas 2013 Award of Excellence

2013 CTBUH Awards

18 October 2016 | Oklahoma City

CTBUH 2016 China Conference - Panel,"Tall Buildings and Context: How High Can We Go and Why Should We?"

Tuesday, October 18, 2016. Shenzhen, China. Ron Klemencic, Magnusson Klemencic Associates; Karl Almstead, Turner Construction Company; Andrew Nicholson, CBRE; Jon Pickard, Pickard Chilton; Ian Smith,...

18 October 2016 | Oklahoma City

CTBUH Video Interview – Jon Pickard

Jon Pickard of Pickard Chilton is interviewed by Chris Bentley during the 2016 CTBUH China Conference. Jon discusses the local economic impacts of tall buildings.